{"id":33,"date":"2008-06-05T10:02:53","date_gmt":"2008-06-05T14:02:53","guid":{"rendered":"http:\/\/windenergy7.com\/turbines\/?p=33"},"modified":"2017-01-27T22:34:08","modified_gmt":"2017-01-28T03:34:08","slug":"interconnection-standards-georgia-wind-energy","status":"publish","type":"post","link":"http:\/\/windenergy7.com\/turbines\/wind-energy\/interconnection-standards-georgia-wind-energy\/","title":{"rendered":"Interconnection Standards &#8211; Wind Energy in Georgia"},"content":{"rendered":"<p>.<br \/>\n.<br \/>\n<strong>Georgia Interconnection Standards<\/strong><\/p>\n<p><strong>Incentive Type: <\/strong>Interconnection<\/p>\n<p><strong>Eligible Renewable\/Other Technologies:<\/strong> Photovoltaics, Wind, Fuel Cells<\/p>\n<p><strong>Applicable Sectors: <\/strong>Commercial, Industrial, Residential, Nonprofit, Schools, Local Government, State Government, Fed. Government<\/p>\n<p><strong>Special Rules for Net-Metered Systems?<\/strong> Yes<\/p>\n<p><strong>Limit on System Size\/Overall Enrollment: <\/strong>10 kW (residential), 100 kW (commercial); 0.2% of utility&#8217;s peak load for previous year<\/p>\n<p><strong>Standard Interconnection Agreement?<\/strong> No (contact Georgia Power)<\/p>\n<p><strong>Additional Insurance Requirements?<\/strong> None<\/p>\n<p><strong>External Disconnect Required?<\/strong> Not specified<\/p>\n<p><strong>Rules for Non-Net-Metered DG?<\/strong> No<\/p>\n<p><strong>Authority 1:<\/strong> O.C.G. \u00a7 46-3-56<br \/>\nDate Enacted: 4\/28\/2001<br \/>\nEffective Date: 6\/1\/2002<\/p>\n<p><strong>Summary: <\/strong>\u00a0<br \/>\nThe Georgia Cogeneration and Distributed Generation Act of 2001 allows residential electricity customers with photovoltaic systems, wind-energy systems or fuel cells with a maximum capacity of 10 kilowatts (kW), and commercial facilities up to 100 kW, to connect to the grid. A utility is not required to enroll customers beyond 0.2% of its peak load for the previous year. \u00a0<br \/>\n\u00a0<br \/>\nInterconnected customers must comply with all national standards: Institute of Electrical and Electronic Engineers (IEEE), Underwriters Laboratories (UL), and National Electrical Safety Code (NEC). Furthermore, the Georgia Public Service Commission (PSC) may adopt additional safety, power-quality and interconnection requirements. There is no provision in Georgia&#8217;s interconnection standards requiring customers to install a manual external disconnect device. Utilities may not require additional tests or additional liability insurance. \u00a0<br \/>\n\u00a0<br \/>\nGeorgia Power, the state&#8217;s largest utility, has established a green-power program, whereby the power generated by eligible renewable-energy systems connected to the grid under the utility&#8217;s net-metering provisions is sold to other customers. System owners are paid for generation at a higher rate than the rate at which they would be compensated under standard net metering. \u00a0<\/p>\n<p><strong>Contact: <\/strong>\u00a0<br \/>\nRita Kilpatrick<br \/>\nSouthern Alliance for Clean Energy<br \/>\n427 Moreland Avenue NE, Suite 100<br \/>\nAtlanta, GA 30307<br \/>\nPhone: (404) 659-5675<br \/>\nFax: (770) 234-3909<br \/>\nE-Mail: kilpatrick@cleanenergy.org<br \/>\nWeb site: http:\/\/www.cleanenergy.org<br \/>\n\u00a0<br \/>\n<strong>Public Information:<\/strong><br \/>\n(Georgia PSC)<br \/>\nGeorgia Public Service Commission<br \/>\n244 Washington Street, SW<br \/>\nAtlanta, GA 30334<br \/>\nPhone: (800) 282-5813<br \/>\nPhone 2: (404) 656-4501<br \/>\nFax: (404) 656-2341<br \/>\nE-Mail:gapsc@psc.state.ga.us<br \/>\nWeb site:\u00a0 http:\/\/www.psc.state.ga.us<\/p>\n<p>If you are interested in starting a wind project for your residence or acreage, contact us. To Buy a Wind Turbine or Become a Dealer, Please fill out our <b><u><a title=\"Home Wind Turbine Contact\" href=\"http:\/\/windenergy7.com\/contact.php\" target=\"_blank\">Contact Form<\/a><\/u><\/b>.  The system will automatically send you some additional info.<br \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>. . Georgia Interconnection Standards Incentive Type: Interconnection Eligible Renewable\/Other Technologies: Photovoltaics, Wind, Fuel Cells Applicable Sectors: Commercial, Industrial, Residential, Nonprofit, Schools, Local Government, State Government, Fed. Government Special Rules for Net-Metered Systems? Yes Limit on System Size\/Overall Enrollment: 10 kW (residential), 100 kW (commercial); 0.2% of utility&#8217;s peak load for previous year Standard Interconnection [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[11],"tags":[179,171,174,172,173,176,17,177,175,178],"class_list":["post-33","post","type-post","status-publish","format-standard","hentry","category-wind-energy","tag-green-power","tag-interconnect-standard","tag-interconnect-standards","tag-interconnection-standard","tag-interconnection-standards","tag-interconnection-standards-for","tag-renewable-energy","tag-standard-for-interconnecting","tag-standard-interconnection-agreement","tag-wind"],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/posts\/33"}],"collection":[{"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/comments?post=33"}],"version-history":[{"count":7,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/posts\/33\/revisions"}],"predecessor-version":[{"id":2095,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/posts\/33\/revisions\/2095"}],"wp:attachment":[{"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/media?parent=33"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/categories?post=33"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/windenergy7.com\/turbines\/wp-json\/wp\/v2\/tags?post=33"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}